cort efda9b02b6 Implement fast terminator detection (200ms inactivity threshold)
- Add fast terminator detection: when new stream tries to start, check if current stream inactive >200ms
- If inactive >200ms, end old stream immediately and allow new one (provides ~200ms turnaround)
- Add end_reason field to stream_end events ('fast_terminator' or 'timeout')
- Update dashboard to display end_reason in event log
- Mark sync pattern terminator detection as TODO (not yet working, needs investigation)
- Mark LC extraction from sync frames as TODO (may need FEC decoding)
- Update all documentation to reflect new approach
- Remove negative language about 'limitations' - frame as TODO items instead

This provides acceptable fast turnaround (~200ms) without needing to decode ETSI sync
patterns, which don't appear to match in Homebrew protocol packets (may need FEC or
other decoding that requires investigation).