Files
hblink3/bridge.py
T
Cort BuffingtonandClaude Opus 4.8 fdf1b33ee8 bridge.py: log slot collisions once per stream, not per frame
The source-side "collided with existing call" warning fired on every dropped
frame, flooding the log when streams contend for a slot (e.g. several peers on
one master keying the same talkgroup). Gate it on a per-slot RX_COLLISION_SID so
each contending stream is reported once, matching the once-per-stream behavior
of the target-side contention log. Routing/emissions are unchanged; this is
logging volume only. The dashboard's stale-stream reaper stays as-is for
defense-in-depth (non-local dashboard, hblink failure, etc.).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-25 07:13:59 -05:00

1071 lines
60 KiB
Python
Executable File

#!/usr/bin/env python
#
###############################################################################
# Copyright (C) 2016-2019 Cortney T. Buffington, N0MJS <n0mjs@me.com>
#
# This program is free software; you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation; either version 3 of the License, or
# (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program; if not, write to the Free Software Foundation,
# Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA
###############################################################################
'''
This application, in conjuction with it's rule file (rules.py) will
work like a "conference bridge". This is similar to what most hams think of as a
reflector. You define conference bridges and any system joined to that conference
bridge will both receive traffic from, and send traffic to any other system
joined to the same conference bridge. It does not provide end-to-end connectivity
as each end system must individually be joined to a conference bridge (a name
you create in the configuraiton file) to pass traffic.
This program currently only works with group voice calls.
'''
# Python modules we need
import sys
from bitarray import bitarray
from time import time
import importlib.util
import asyncio
# Things we import from the main hblink module
from hblink import HBSYSTEM, OPENBRIDGE, systems, hblink_handler, reportFactory, REPORT_OPCODES, mk_aliases, run_periodic
from dmr_utils3.utils import bytes_3, int_id, get_alias
from dmr_utils3 import decode, bptc, const
import config
import log
from const import *
# The module needs logging, but handlers, etc. are controlled by the parent
import logging
logger = logging.getLogger(__name__)
# Does anybody read this stuff? There's a PEP somewhere that says I should do this.
__author__ = 'Cortney T. Buffington, N0MJS'
__copyright__ = 'Copyright (c) 2016-2019 Cortney T. Buffington, N0MJS and the K0USY Group'
__credits__ = 'Colin Durbridge, G4EML, Steve Zingman, N4IRS; Mike Zingman, N4IRR; Jonathan Naylor, G4KLX; Hans Barthen, DL5DI; Torsten Shultze, DG1HT'
__license__ = 'GNU GPLv3'
__maintainer__ = 'Cort Buffington, N0MJS'
__email__ = 'n0mjs@me.com'
# Module gobal varaibles
# Dictionary for dynamically mapping unit (subscriber) to a system.
# This is for pruning unit-to-uint calls to not broadcast once the
# target system for a unit is identified
# format 'unit_id': ('SYSTEM', time)
UNIT_MAP = {}
# Routing indexes derived from BRIDGES once at startup by index_bridges(). They
# turn the per-frame "which bridges does this source feed?" question into an O(1)
# dict lookup instead of a full scan of every bridge and member on every packet.
# Keys (system, ts, tgid / system) are immutable per member; ACTIVE is read live
# at packet time, so the indexes only need rebuilding if bridge MEMBERSHIP changes.
BRIDGE_SRC_INDEX = {}
BRIDGE_BY_SYSTEM = {}
# The reporting server manager; assigned in async_main when REPORT is enabled.
# Module-global so the rule-timer and stream-trimmer loops can reach it.
report_server = None
# Generate the full (header & terminator) and embedded Link Control for a
# re-targeted group stream. Returns (H_LC, T_LC, EMB_LC). Pure -- no side effects.
def gen_lcs(_dst_lc):
return bptc.encode_header_lc(_dst_lc), bptc.encode_terminator_lc(_dst_lc), bptc.encode_emblc(_dst_lc)
# Rewrite the DMR payload's embedded/full Link Control for a re-targeted group
# stream and return the new 33-byte payload. The middle (voice/sync) bits are
# preserved from the source packet; only the LC portions are replaced. Pure.
def embed_lc(_dmrpkt, _frame_type, _dtype_vseq, _h_lc, _t_lc, _emb_lc):
dmrbits = bitarray(endian='big')
dmrbits.frombytes(_dmrpkt)
# Create a voice header packet (FULL LC)
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _h_lc[0:98] + dmrbits[98:166] + _h_lc[98:197]
# Create a voice terminator packet (FULL LC)
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _t_lc[0:98] + dmrbits[98:166] + _t_lc[98:197]
# Create a Burst B-E packet (Embedded LC)
elif _dtype_vseq in [1,2,3,4]:
dmrbits = dmrbits[0:116] + _emb_lc[_dtype_vseq] + dmrbits[148:264]
return dmrbits.tobytes()
# Timed loop used for reporting HBP status
#
# REPORT BASED ON THE TYPE SELECTED IN THE MAIN CONFIG FILE
def config_reports(_config, _factory):
def reporting_loop(logger, _server):
logger.debug('(REPORT) Periodic reporting loop started')
_server.send_config()
_server.send_bridge()
logger.info('(REPORT) HBlink TCP reporting server configured')
report_server = _factory(_config)
report_server.clients = []
loop = asyncio.get_event_loop()
loop.create_task(report_server.start(_config['REPORTS']['REPORT_PORT']))
loop.create_task(run_periodic(_config['REPORTS']['REPORT_INTERVAL'],
reporting_loop, '(REPORT) reporting', logger, report_server))
return report_server
# Import Bridging rules
# Note: A stanza *must* exist for any MASTER or CLIENT configured in the main
# configuration file and listed as "active". It can be empty,
# but it has to exist.
def make_bridges(_rules):
# Convert integer GROUP ID numbers from the config into hex strings
# we need to send in the actual data packets.
for _bridge in _rules:
for _system in _rules[_bridge]:
if _system['SYSTEM'] not in CONFIG['SYSTEMS']:
sys.exit('ERROR: Conference bridge "{}" references a system named "{}" that is not enabled in the main configuration'.format(_bridge, _system['SYSTEM']))
_system['TGID'] = bytes_3(_system['TGID'])
for i, e in enumerate(_system['ON']):
_system['ON'][i] = bytes_3(_system['ON'][i])
for i, e in enumerate(_system['OFF']):
_system['OFF'][i] = bytes_3(_system['OFF'][i])
_system['TIMEOUT'] = _system['TIMEOUT']*60
if _system['ACTIVE'] == True:
_system['TIMER'] = time() + _system['TIMEOUT']
else:
_system['TIMER'] = time()
return _rules
# Build the routing indexes from the processed BRIDGES structure. Call once after
# make_bridges() (and again only if bridge membership is ever rebuilt at runtime).
# src_index: (system, ts, tgid) -> [(bridge_name, source_member, sibling_members), ...]
# by_system: system -> [(bridge_name, member), ...] (for the in-band signalling pass)
def index_bridges(_bridges):
src_index = {}
by_system = {}
for _bridge in _bridges:
_members = _bridges[_bridge]
for _member in _members:
src_index.setdefault((_member['SYSTEM'], _member['TS'], _member['TGID']), []).append((_bridge, _member, _members))
by_system.setdefault(_member['SYSTEM'], []).append((_bridge, _member))
return src_index, by_system
# Run this every minute for rule timer updates
def rule_timer_loop():
global UNIT_MAP
logger.debug('(ROUTER) routerHBP Rule timer loop started')
_now = time()
for _bridge in BRIDGES:
for _system in BRIDGES[_bridge]:
if _system['TO_TYPE'] == 'ON':
if _system['ACTIVE'] == True:
if _system['TIMER'] < _now:
_system['ACTIVE'] = False
logger.info('(ROUTER) Conference Bridge TIMEOUT: DEACTIVATE System: %s, Bridge: %s, TS: %s, TGID: %s', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']))
else:
timeout_in = _system['TIMER'] - _now
logger.info('(ROUTER) Conference Bridge ACTIVE (ON timer running): System: %s Bridge: %s, TS: %s, TGID: %s, Timeout in: %.2fs,', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']), timeout_in)
elif _system['ACTIVE'] == False:
logger.debug('(ROUTER) Conference Bridge INACTIVE (no change): System: %s Bridge: %s, TS: %s, TGID: %s', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']))
elif _system['TO_TYPE'] == 'OFF':
if _system['ACTIVE'] == False:
if _system['TIMER'] < _now:
_system['ACTIVE'] = True
logger.info('(ROUTER) Conference Bridge TIMEOUT: ACTIVATE System: %s, Bridge: %s, TS: %s, TGID: %s', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']))
else:
timeout_in = _system['TIMER'] - _now
logger.info('(ROUTER) Conference Bridge INACTIVE (OFF timer running): System: %s Bridge: %s, TS: %s, TGID: %s, Timeout in: %.2fs,', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']), timeout_in)
elif _system['ACTIVE'] == True:
logger.debug('(ROUTER) Conference Bridge ACTIVE (no change): System: %s Bridge: %s, TS: %s, TGID: %s', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']))
else:
logger.debug('(ROUTER) Conference Bridge NO ACTION: System: %s, Bridge: %s, TS: %s, TGID: %s', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']))
_then = _now - 60
remove_list = []
for unit in UNIT_MAP:
if UNIT_MAP[unit][1] < (_then):
remove_list.append(unit)
for unit in remove_list:
del UNIT_MAP[unit]
logger.debug('Removed unit(s) %s from UNIT_MAP', remove_list)
# Push refreshed bridge state to consumers after a rule-timer pass
if CONFIG['REPORTS']['REPORT'] and report_server:
report_server.send_bridge()
# run this every 10 seconds to trim orphaned stream ids
def stream_trimmer_loop():
# Runs once a second -- intentionally silent per-pass; it only logs when it
# actually times out a stream.
_now = time()
for system in systems:
# HBP systems, master and peer
if CONFIG['SYSTEMS'][system]['MODE'] != 'OPENBRIDGE':
for slot in range(1,3):
_slot = systems[system].STATUS[slot]
# RX slot check -- time out a stream with no audio for STREAM_TIMEOUT
if not _slot['RX_TERMINATED'] and _slot['RX_TIME'] < _now - STREAM_TIMEOUT:
logger.info('(%s) *TIME OUT* RX STREAM ID: %s SUB: %s TGID %s, TS %s, Duration: %.2f', \
system, int_id(_slot['RX_STREAM_ID']), int_id(_slot['RX_RFS']), int_id(_slot['RX_TGID']), slot, _slot['RX_TIME'] - _slot['RX_START'])
systems[system]._end_slot_stream(slot)
# TX slot check
if not _slot['TX_TERMINATED'] and _slot['TX_TIME'] < _now - STREAM_TIMEOUT:
_slot['TX_TERMINATED'] = True
logger.info('(%s) *TIME OUT* TX STREAM ID: %s SUB: %s TGID %s, TS %s, Duration: %.2f', \
system, int_id(_slot['TX_STREAM_ID']), int_id(_slot['TX_RFS']), int_id(_slot['TX_TGID']), slot, _slot['TX_TIME'] - _slot['TX_START'])
if CONFIG['REPORTS']['REPORT']:
systems[system]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(system, int_id(_slot['TX_STREAM_ID']), int_id(_slot['TX_PEER']), int_id(_slot['TX_RFS']), slot, int_id(_slot['TX_TGID']), _slot['TX_TIME'] - _slot['TX_START']).encode(encoding='utf-8', errors='ignore'))
# OBP systems
# We can't delete items from a dicationry that's being iterated, so we have to make a temporarly list of entrys to remove later
if CONFIG['SYSTEMS'][system]['MODE'] == 'OPENBRIDGE':
remove_list = []
for stream_id in systems[system].STATUS:
if systems[system].STATUS[stream_id]['LAST'] < _now - STREAM_TIMEOUT:
remove_list.append(stream_id)
for stream_id in remove_list:
if stream_id in systems[system].STATUS:
_stream = systems[system].STATUS[stream_id]
_sysconfig = CONFIG['SYSTEMS'][system]
if systems[system].STATUS[stream_id]['ACTIVE']:
logger.info('(%s) *TIME OUT* STREAM ID: %s SUB: %s PEER: %s TYPE: %s DST ID: %s TS 1 Duration: %.2f', \
system, int_id(stream_id), get_alias(int_id(_stream['RFS']), subscriber_ids), get_alias(int_id(_sysconfig['NETWORK_ID']), peer_ids), _stream['TYPE'], get_alias(int_id(_stream['DST']), talkgroup_ids), _stream['LAST'] - _stream['START'])
if CONFIG['REPORTS']['REPORT']:
if _stream['TYPE'] == 'GROUP':
systems[system]._report.send_bridgeEvent('GROUP VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(system, int_id(stream_id), int_id(_sysconfig['NETWORK_ID']), int_id(_stream['RFS']), 1, int_id(_stream['DST']), _stream['LAST'] - _stream['START']).encode(encoding='utf-8', errors='ignore'))
elif _stream['TYPE'] == 'UNIT':
systems[system]._report.send_bridgeEvent('UNIT VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(system, int_id(stream_id), int_id(_sysconfig['NETWORK_ID']), int_id(_stream['RFS']), 1, int_id(_stream['DST']), _stream['LAST'] - _stream['START']).encode(encoding='utf-8', errors='ignore'))
removed = systems[system].STATUS.pop(stream_id)
else:
logger.error('(%s) Attemped to remove OpenBridge Stream ID %s not in the Stream ID list: %s', system, int_id(stream_id), [id for id in systems[system].STATUS])
class routerOBP(OPENBRIDGE):
def __init__(self, _name, _config, _report):
OPENBRIDGE.__init__(self, _name, _config, _report)
self.name = _name
self.STATUS = {}
# list of self._targets for unit (subscriber, private) calls
self._targets = []
def group_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data):
pkt_time = time()
dmrpkt = _data[20:53]
_bits = _data[15]
# Is this a new call stream?
if (_stream_id not in self.STATUS):
# This is a new call stream
self.STATUS[_stream_id] = {
'START': pkt_time,
'CONTENTION':False,
'RFS': _rf_src,
'TYPE': 'GROUP',
'DST': _dst_id,
'ACTIVE': True
}
# If we can, use the LC from the voice header as to keep all options intact
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
decoded = decode.voice_head_term(dmrpkt)
self.STATUS[_stream_id]['LC'] = decoded['LC']
# If we don't have a voice header then don't wait to decode the Embedded LC
# just make a new one from the HBP header. This is good enough, and it saves lots of time
else:
self.STATUS[_stream_id]['LC'] = LC_OPT + _dst_id + _rf_src
logger.info('(%s) *GROUP CALL START* OBP STREAM ID: %s SUB: %s (%s) PEER: %s (%s) TGID %s (%s), TS %s', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot)
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('GROUP VOICE,START,RX,{},{},{},{},{},{}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id)).encode(encoding='utf-8', errors='ignore'))
self.STATUS[_stream_id]['LAST'] = pkt_time
# Hand each active target the frame; the target system applies its own
# admission/contention policy and egress framing (see bridge_group).
_src_lc = self.STATUS[_stream_id]['LC']
for _bridge, _system, _members in BRIDGE_SRC_INDEX.get((self._system, _slot, _dst_id), ()):
if _system['ACTIVE'] == True:
for _target in _members:
if (_target['SYSTEM'] != self._system) and (_target['ACTIVE']):
systems[_target['SYSTEM']].bridge_group(
self, _bridge, _target, _system['TS'], _src_lc, b'\x00\x00',
_peer_id, _rf_src, _dst_id, _stream_id, _slot,
_frame_type, _dtype_vseq, _data, pkt_time)
# Final actions - Is this a voice terminator?
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM):
call_duration = pkt_time - self.STATUS[_stream_id]['START']
logger.info('(%s) *GROUP CALL END* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) TGID %s (%s), TS %s, Duration: %.2f', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, call_duration)
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('GROUP VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), call_duration).encode(encoding='utf-8', errors='ignore'))
self.STATUS[_stream_id]['ACTIVE'] = False
logger.debug('(%s) OpenBridge sourced call stream end, remove terminated Stream ID: %s', self._system, int_id(_stream_id))
# Contention-log gate (source side): log a target-contention message once per
# source stream. Called by an HBP target's bridge_group.
def should_log_contention(self, _stream_id, _slot, _frame_type, _dtype_vseq):
if self.STATUS[_stream_id]['CONTENTION'] == False:
self.STATUS[_stream_id]['CONTENTION'] = True
return True
return False
# Forward a bridged group frame INTO this OpenBridge (this system is the
# target). OpenBridge carries unlimited concurrent streams (keyed by stream
# id), is effectively TS1, and carries no BER/RSSI trailer.
def bridge_group(self, _src, _bridge, _target, _src_ts, _src_lc, _ber_rssi,
_peer_id, _rf_src, _dst_id, _stream_id, _slot,
_frame_type, _dtype_vseq, _data, _pkt_time):
_bits = _data[15]
_dmrpkt = _data[20:53]
_target_status = self.STATUS
# Is this a new call stream on the target?
if (_stream_id not in _target_status):
_target_status[_stream_id] = {
'START': _pkt_time,
'CONTENTION':False,
'RFS': _rf_src,
'TYPE': 'GROUP',
'DST': _dst_id,
'ACTIVE': True
}
# Generate LCs (full and EMB) for the TX stream
dst_lc = b''.join([_src_lc[0:3], _target['TGID'], _rf_src])
_target_status[_stream_id]['H_LC'], _target_status[_stream_id]['T_LC'], _target_status[_stream_id]['EMB_LC'] = gen_lcs(dst_lc)
logger.info('(%s) Conference Bridge: %s, Call Bridged to OBP System: %s TS: %s, TGID: %s', _src._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
# Record the time of this packet so we can later identify a stale stream
_target_status[_stream_id]['LAST'] = _pkt_time
# Clear the TS bit -- all OpenBridge streams are effectively on TS1
_tmp_bits = _bits & ~(1 << 7)
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
_dmrpkt = embed_lc(_dmrpkt, _frame_type, _dtype_vseq, _target_status[_stream_id]['H_LC'], _target_status[_stream_id]['T_LC'], _target_status[_stream_id]['EMB_LC'])
# On the voice terminator, finalize the target stream and report the call end
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM and CONFIG['REPORTS']['REPORT']:
call_duration = _pkt_time - _target_status[_stream_id]['START']
_target_status[_stream_id]['ACTIVE'] = False
self._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
_tmp_data = b''.join([_tmp_data, _dmrpkt])
self.send_system(_tmp_data)
# Drop the target stream on the terminator (the trimmer also cleans up)
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM and _stream_id in _target_status:
_target_status.pop(_stream_id)
def unit_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data):
global UNIT_MAP
pkt_time = time()
dmrpkt = _data[20:53]
_bits = _data[15]
# Make/update this unit in the UNIT_MAP cache
UNIT_MAP[_rf_src] = (self.name, pkt_time)
# Is this a new call stream?
if (_stream_id not in self.STATUS):
# This is a new call stream
self.STATUS[_stream_id] = {
'START': pkt_time,
'CONTENTION':False,
'RFS': _rf_src,
'TYPE': 'UNIT',
'DST': _dst_id,
'ACTIVE': True
}
# Create a destination list for the call:
if _dst_id in UNIT_MAP:
if UNIT_MAP[_dst_id][0] != self._system:
self._targets = [UNIT_MAP[_dst_id][0]]
else:
self._targets = []
logger.error('UNIT call to a subscriber on the same system, send nothing')
else:
self._targets = list(UNIT)
self._targets.remove(self._system)
# This is a new call stream, so log & report
logger.info('(%s) *UNIT CALL START* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) UNIT: %s (%s), TS: %s, FORWARD: %s', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, self._targets)
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('UNIT VOICE,START,RX,{},{},{},{},{},{},{}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), self._targets).encode(encoding='utf-8', errors='ignore'))
# Record the time of this packet so we can later identify a stale stream
self.STATUS[_stream_id]['LAST'] = pkt_time
for _target in self._targets:
systems[_target].bridge_unit(
self, _peer_id, _rf_src, _dst_id, _stream_id, _slot,
_frame_type, _dtype_vseq, _data, pkt_time)
# Final actions - Is this a voice terminator?
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM):
self._targets = []
call_duration = pkt_time - self.STATUS[_stream_id]['START']
logger.info('(%s) *UNIT CALL END* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) UNIT %s (%s), TS %s, Duration: %.2f', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, call_duration)
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('UNIT VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), call_duration).encode(encoding='utf-8', errors='ignore'))
# Forward a bridged unit (private) call INTO this OpenBridge (this system is
# the target). Unit calls are not TGID/LC rewritten; the slot bit is cleared
# unless BOTH_SLOTS is set, and there is no BER/RSSI trailer.
def bridge_unit(self, _src, _peer_id, _rf_src, _dst_id, _stream_id, _slot,
_frame_type, _dtype_vseq, _data, _pkt_time):
_bits = _data[15]
_dmrpkt = _data[20:53]
_target_status = self.STATUS
if (_stream_id not in _target_status):
_target_status[_stream_id] = {
'START': _pkt_time,
'CONTENTION':False,
'RFS': _rf_src,
'TYPE': 'UNIT',
'DST': _dst_id,
'ACTIVE': True
}
logger.info('(%s) Unit call bridged to OBP System: %s TS: %s, UNIT: %s', _src._system, self._system, _slot if self._config['BOTH_SLOTS'] else 1, int_id(_dst_id))
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('UNIT VOICE,START,TX,{},{},{},{},{},{}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id)).encode(encoding='utf-8', errors='ignore'))
# Record the time of this packet so we can later identify a stale stream
_target_status[_stream_id]['LAST'] = _pkt_time
# Clear the TS bit and follow proper OBP definition, unless BOTH_SLOTS is set
if self._config['BOTH_SLOTS']:
_tmp_bits = _bits
else:
_tmp_bits = _bits & ~(1 << 7)
_out = b''.join([_data[:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20], _dmrpkt])
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM):
_target_status[_stream_id]['ACTIVE'] = False
self.send_system(_out)
# Drop the target stream on the terminator (the trimmer also cleans up)
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM) and _stream_id in _target_status:
_target_status.pop(_stream_id)
def dmrd_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data):
if _call_type == 'group':
self.group_received(_peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data)
elif _call_type == 'unit':
self.unit_received(_peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data)
elif _call_type == 'vcsbk':
logger.debug('CSBK recieved, but HBlink does not process them currently')
else:
logger.error('Unknown call type recieved -- not processed')
class routerHBP(HBSYSTEM):
def __init__(self, _name, _config, _report):
HBSYSTEM.__init__(self, _name, _config, _report)
self.name = _name
# list of self._targets for unit (subscriber, private) calls
self._targets = []
# Status information for the system, TS1 & TS2
# 1 & 2 are "timeslot"
# In TX_EMB_LC, 2-5 are burst B-E
self.STATUS = {
1: {
'RX_START': time(),
'TX_START': time(),
'RX_SEQ': 0,
'RX_RFS': b'\x00',
'TX_RFS': b'\x00',
'RX_PEER': b'\x00',
'TX_PEER': b'\x00',
'RX_STREAM_ID': b'\x00',
'TX_STREAM_ID': b'\x00',
'RX_TGID': b'\x00\x00\x00',
'TX_TGID': b'\x00\x00\x00',
'RX_TIME': time(),
'TX_TIME': time(),
'RX_TYPE': HBPF_SLT_VTERM,
'TX_TYPE': HBPF_SLT_VTERM,
# Explicit "stream has ended" flags. RX_/TX_TYPE hold the last
# frame's _dtype_vseq, which for voice bursts cycles 0..5 and so
# collides with HBPF_SLT_VTERM (==2) -- using it as the terminated
# sentinel drops the END of any stream whose last burst was vseq 2.
'RX_TERMINATED': True,
'TX_TERMINATED': True,
# Last stream-id we logged a slot collision for, so a contending
# stream is reported once -- not once per colliding frame.
'RX_COLLISION_SID': b'\x00',
'RX_CT': 'GROUP VOICE',
'RX_LC': b'\x00',
'TX_H_LC': b'\x00',
'TX_T_LC': b'\x00',
'TX_EMB_LC': {
1: b'\x00',
2: b'\x00',
3: b'\x00',
4: b'\x00',
}
},
2: {
'RX_START': time(),
'TX_START': time(),
'RX_SEQ': 0,
'RX_RFS': b'\x00',
'TX_RFS': b'\x00',
'RX_PEER': b'\x00',
'TX_PEER': b'\x00',
'RX_STREAM_ID': b'\x00',
'TX_STREAM_ID': b'\x00',
'RX_TGID': b'\x00\x00\x00',
'TX_TGID': b'\x00\x00\x00',
'RX_TIME': time(),
'TX_TIME': time(),
'RX_TYPE': HBPF_SLT_VTERM,
'TX_TYPE': HBPF_SLT_VTERM,
# Explicit "stream has ended" flags. RX_/TX_TYPE hold the last
# frame's _dtype_vseq, which for voice bursts cycles 0..5 and so
# collides with HBPF_SLT_VTERM (==2) -- using it as the terminated
# sentinel drops the END of any stream whose last burst was vseq 2.
'RX_TERMINATED': True,
'TX_TERMINATED': True,
# Last stream-id we logged a slot collision for, so a contending
# stream is reported once -- not once per colliding frame.
'RX_COLLISION_SID': b'\x00',
'RX_CT': 'GROUP VOICE',
'RX_LC': b'\x00',
'TX_H_LC': b'\x00',
'TX_T_LC': b'\x00',
'TX_EMB_LC': {
1: b'\x00',
2: b'\x00',
3: b'\x00',
4: b'\x00',
}
}
}
# If a timeslot is holding a stream that never sent a terminator (it was
# superseded by a new stream, or it timed out on the trimmer), declare it
# ended and emit a matching END so consumers don't leak it. No-op if the slot
# already ended cleanly. Used by both the new-stream path and the trimmer.
def _end_slot_stream(self, _slot):
st = self.STATUS[_slot]
if st['RX_TERMINATED']:
return
st['RX_TERMINATED'] = True
if CONFIG['REPORTS']['REPORT'] and self._report:
duration = st['RX_TIME'] - st['RX_START']
self._report.send_bridgeEvent('{},END,RX,{},{},{},{},{},{},{:.2f}'.format(
st.get('RX_CT', 'GROUP VOICE'), self._system, int_id(st['RX_STREAM_ID']),
int_id(st['RX_PEER']), int_id(st['RX_RFS']), _slot, int_id(st['RX_TGID']),
duration).encode(encoding='utf-8', errors='ignore'))
def group_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data):
global UNIT_MAP
pkt_time = time()
dmrpkt = _data[20:53]
_bits = _data[15]
# Make/update an entry in the UNIT_MAP for this subscriber
UNIT_MAP[_rf_src] = (self.name, pkt_time)
# Is this a new call stream?
if (_stream_id != self.STATUS[_slot]['RX_STREAM_ID']):
if (not self.STATUS[_slot]['RX_TERMINATED']) and (pkt_time < (self.STATUS[_slot]['RX_TIME'] + STREAM_TO)) and (_rf_src != self.STATUS[_slot]['RX_RFS']):
if self.STATUS[_slot]['RX_COLLISION_SID'] != _stream_id:
self.STATUS[_slot]['RX_COLLISION_SID'] = _stream_id
logger.warning('(%s) Packet received with STREAM ID: %s <FROM> SUB: %s PEER: %s <TO> TGID %s, SLOT %s collided with existing call', self._system, int_id(_stream_id), int_id(_rf_src), int_id(_peer_id), int_id(_dst_id), _slot)
return
# A new stream is taking the slot: end any prior un-terminated stream first
self._end_slot_stream(_slot)
# This is a new call stream
self.STATUS[_slot]['RX_START'] = pkt_time
self.STATUS[_slot]['RX_TERMINATED'] = False
self.STATUS[_slot]['RX_CT'] = 'GROUP VOICE'
logger.info('(%s) *GROUP CALL START* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) TGID %s (%s), TS %s', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot)
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('GROUP VOICE,START,RX,{},{},{},{},{},{}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id)).encode(encoding='utf-8', errors='ignore'))
# If we can, use the LC from the voice header as to keep all options intact
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
decoded = decode.voice_head_term(dmrpkt)
self.STATUS[_slot]['RX_LC'] = decoded['LC']
# If we don't have a voice header then don't wait to decode it from the Embedded LC
# just make a new one from the HBP header. This is good enough, and it saves lots of time
else:
self.STATUS[_slot]['RX_LC'] = LC_OPT + _dst_id + _rf_src
# Hand each active target the frame; the target system applies its own
# admission/contention policy and egress framing (see bridge_group).
_src_lc = self.STATUS[_slot]['RX_LC']
for _bridge, _system, _members in BRIDGE_SRC_INDEX.get((self._system, _slot, _dst_id), ()):
if _system['ACTIVE'] == True:
for _target in _members:
if _target['SYSTEM'] != self._system and _target['ACTIVE']:
systems[_target['SYSTEM']].bridge_group(
self, _bridge, _target, _system['TS'], _src_lc, _data[53:55],
_peer_id, _rf_src, _dst_id, _stream_id, _slot,
_frame_type, _dtype_vseq, _data, pkt_time)
# Final actions - Is this a voice terminator?
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM) and (not self.STATUS[_slot]['RX_TERMINATED']):
self.STATUS[_slot]['RX_TERMINATED'] = True
call_duration = pkt_time - self.STATUS[_slot]['RX_START']
logger.info('(%s) *GROUP CALL END* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) TGID %s (%s), TS %s, Duration: %.2f', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, call_duration)
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('GROUP VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), call_duration).encode(encoding='utf-8', errors='ignore'))
#
# Begin in-band signalling for call end. This has nothign to do with routing traffic directly.
#
# Iterate the rules dictionary
# Indexed lookup of this system's bridge memberships for in-band signalling.
for _bridge, _system in BRIDGE_BY_SYSTEM.get(self._system, ()):
# TGID matches a rule source, reset its timer
if _slot == _system['TS'] and _dst_id == _system['TGID'] and ((_system['TO_TYPE'] == 'ON' and (_system['ACTIVE'] == True)) or (_system['TO_TYPE'] == 'OFF' and _system['ACTIVE'] == False)):
_system['TIMER'] = pkt_time + _system['TIMEOUT']
logger.info('(%s) Transmission match for Bridge: %s. Reset timeout to %s', self._system, _bridge, _system['TIMER'])
# TGID matches an ACTIVATION trigger
if (_dst_id in _system['ON'] or _dst_id in _system['RESET']) and _slot == _system['TS']:
# Set the matching rule as ACTIVE
if _dst_id in _system['ON']:
if _system['ACTIVE'] == False:
_system['ACTIVE'] = True
_system['TIMER'] = pkt_time + _system['TIMEOUT']
logger.info('(%s) Bridge: %s, connection changed to state: %s', self._system, _bridge, _system['ACTIVE'])
# Cancel the timer if we've enabled an "OFF" type timeout
if _system['TO_TYPE'] == 'OFF':
_system['TIMER'] = pkt_time
logger.info('(%s) Bridge: %s set to "OFF" with an on timer rule: timeout timer cancelled', self._system, _bridge)
# Reset the timer for the rule
if _system['ACTIVE'] == True and _system['TO_TYPE'] == 'ON':
_system['TIMER'] = pkt_time + _system['TIMEOUT']
logger.info('(%s) Bridge: %s, timeout timer reset to: %s', self._system, _bridge, _system['TIMER'] - pkt_time)
# TGID matches an DE-ACTIVATION trigger
if (_dst_id in _system['OFF'] or _dst_id in _system['RESET']) and _slot == _system['TS']:
# Set the matching rule as ACTIVE
if _dst_id in _system['OFF']:
if _system['ACTIVE'] == True:
_system['ACTIVE'] = False
logger.info('(%s) Bridge: %s, connection changed to state: %s', self._system, _bridge, _system['ACTIVE'])
# Cancel the timer if we've enabled an "ON" type timeout
if _system['TO_TYPE'] == 'ON':
_system['TIMER'] = pkt_time
logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
# Reset the timer for the rule
if _system['ACTIVE'] == False and _system['TO_TYPE'] == 'OFF':
_system['TIMER'] = pkt_time + _system['TIMEOUT']
logger.info('(%s) Bridge: %s, timeout timer reset to: %s', self._system, _bridge, _system['TIMER'] - pkt_time)
# Cancel the timer if we've enabled an "ON" type timeout
if _system['ACTIVE'] == True and _system['TO_TYPE'] == 'ON' and _dst_id in _system['OFF']:
_system['TIMER'] = pkt_time
logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
#
# END IN-BAND SIGNALLING
#
# Mark status variables for use later
self.STATUS[_slot]['RX_PEER'] = _peer_id
self.STATUS[_slot]['RX_SEQ'] = _seq
self.STATUS[_slot]['RX_RFS'] = _rf_src
self.STATUS[_slot]['RX_TYPE'] = _dtype_vseq
self.STATUS[_slot]['RX_TGID'] = _dst_id
self.STATUS[_slot]['RX_TIME'] = pkt_time
self.STATUS[_slot]['RX_STREAM_ID'] = _stream_id
# Contention-log gate (source side): log once on the new stream's voice header.
def should_log_contention(self, _stream_id, _slot, _frame_type, _dtype_vseq):
return _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id
# Forward a bridged group frame INTO this HBP repeater system (this system is
# the target). HBP timeslots carry one stream at a time, so this applies the
# contention/group-hangtime policy and preserves the BER/RSSI trailer.
def bridge_group(self, _src, _bridge, _target, _src_ts, _src_lc, _ber_rssi,
_peer_id, _rf_src, _dst_id, _stream_id, _slot,
_frame_type, _dtype_vseq, _data, _pkt_time):
_bits = _data[15]
_dmrpkt = _data[20:53]
_target_status = self.STATUS
_ts = _target['TS']
# BEGIN STANDARD CONTENTION HANDLING -- drop the frame if the target slot
# is busy with, or in group hangtime for, a different call.
if ((_target['TGID'] != _target_status[_ts]['RX_TGID']) and ((_pkt_time - _target_status[_ts]['RX_TIME']) < self._config['GROUP_HANGTIME'])):
if _src.should_log_contention(_stream_id, _slot, _frame_type, _dtype_vseq):
logger.info('(%s) Call not routed to TGID %s, target active or in group hangtime: HBSystem: %s, TS: %s, TGID: %s', _src._system, int_id(_target['TGID']), _target['SYSTEM'], _ts, int_id(_target_status[_ts]['RX_TGID']))
return
if ((_target['TGID'] != _target_status[_ts]['TX_TGID']) and ((_pkt_time - _target_status[_ts]['TX_TIME']) < self._config['GROUP_HANGTIME'])):
if _src.should_log_contention(_stream_id, _slot, _frame_type, _dtype_vseq):
logger.info('(%s) Call not routed to TGID%s, target in group hangtime: HBSystem: %s, TS: %s, TGID: %s', _src._system, int_id(_target['TGID']), _target['SYSTEM'], _ts, int_id(_target_status[_ts]['TX_TGID']))
return
if (_target['TGID'] == _target_status[_ts]['RX_TGID']) and ((_pkt_time - _target_status[_ts]['RX_TIME']) < STREAM_TO):
if _src.should_log_contention(_stream_id, _slot, _frame_type, _dtype_vseq):
logger.info('(%s) Call not routed to TGID%s, matching call already active on target: HBSystem: %s, TS: %s, TGID: %s', _src._system, int_id(_target['TGID']), _target['SYSTEM'], _ts, int_id(_target_status[_ts]['RX_TGID']))
return
if (_target['TGID'] == _target_status[_ts]['TX_TGID']) and (_rf_src != _target_status[_ts]['TX_RFS']) and ((_pkt_time - _target_status[_ts]['TX_TIME']) < STREAM_TO):
if _src.should_log_contention(_stream_id, _slot, _frame_type, _dtype_vseq):
logger.info('(%s) Call not routed for subscriber %s, call route in progress on target: HBSystem: %s, TS: %s, TGID: %s, SUB: %s', _src._system, int_id(_rf_src), _target['SYSTEM'], _ts, int_id(_target_status[_ts]['TX_TGID']), int_id(_target_status[_ts]['TX_RFS']))
return
# Is this a new call stream on the target slot?
if (_target_status[_ts]['TX_STREAM_ID'] != _stream_id):
_target_status[_ts]['TX_START'] = _pkt_time
_target_status[_ts]['TX_TERMINATED'] = False
_target_status[_ts]['TX_TGID'] = _target['TGID']
_target_status[_ts]['TX_STREAM_ID'] = _stream_id
_target_status[_ts]['TX_RFS'] = _rf_src
_target_status[_ts]['TX_PEER'] = _peer_id
# Generate LCs (full and EMB) for the TX stream
dst_lc = b''.join([_src_lc[0:3], _target['TGID'], _rf_src])
_target_status[_ts]['TX_H_LC'], _target_status[_ts]['TX_T_LC'], _target_status[_ts]['TX_EMB_LC'] = gen_lcs(dst_lc)
logger.debug('(%s) Generating TX FULL and EMB LCs for HomeBrew destination: System: %s, TS: %s, TGID: %s', _src._system, _target['SYSTEM'], _ts, int_id(_target['TGID']))
logger.info('(%s) Conference Bridge: %s, Call Bridged to HBP System: %s TS: %s, TGID: %s', _src._system, _bridge, _target['SYSTEM'], _ts, int_id(_target['TGID']))
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _ts, int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
# Set values for the contention handler to test on the next frame
_target_status[_ts]['TX_TIME'] = _pkt_time
_target_status[_ts]['TX_TYPE'] = _dtype_vseq
# Flip the TS bit if the source and target timeslots differ
if _src_ts != _ts:
_tmp_bits = _bits ^ 1 << 7
else:
_tmp_bits = _bits
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
_dmrpkt = embed_lc(_dmrpkt, _frame_type, _dtype_vseq, _target_status[_ts]['TX_H_LC'], _target_status[_ts]['TX_T_LC'], _target_status[_ts]['TX_EMB_LC'])
# On the voice terminator, mark the TX stream ended and report the call end
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM and not _target_status[_ts]['TX_TERMINATED']:
_target_status[_ts]['TX_TERMINATED'] = True
if CONFIG['REPORTS']['REPORT']:
call_duration = _pkt_time - _target_status[_ts]['TX_START']
self._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _ts, int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
_tmp_data = b''.join([_tmp_data, _dmrpkt, _ber_rssi])
self.send_system(_tmp_data)
def unit_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data):
global UNIT_MAP
pkt_time = time()
dmrpkt = _data[20:53]
_bits = _data[15]
# Make/update this unit in the UNIT_MAP cache
UNIT_MAP[_rf_src] = (self.name, pkt_time)
# Is this a new call stream?
if (_stream_id != self.STATUS[_slot]['RX_STREAM_ID']):
# Collision in progress, bail out!
if (not self.STATUS[_slot]['RX_TERMINATED']) and (pkt_time < (self.STATUS[_slot]['RX_TIME'] + STREAM_TO)) and (_rf_src != self.STATUS[_slot]['RX_RFS']):
if self.STATUS[_slot]['RX_COLLISION_SID'] != _stream_id:
self.STATUS[_slot]['RX_COLLISION_SID'] = _stream_id
logger.warning('(%s) Packet received with STREAM ID: %s <FROM> SUB: %s PEER: %s <TO> UNIT %s, SLOT %s collided with existing call', self._system, int_id(_stream_id), int_id(_rf_src), int_id(_peer_id), int_id(_dst_id), _slot)
return
# A new stream is taking the slot: end any prior un-terminated stream first
self._end_slot_stream(_slot)
# Create a destination list for the call:
if _dst_id in UNIT_MAP:
if UNIT_MAP[_dst_id][0] != self._system:
self._targets = [UNIT_MAP[_dst_id][0]]
else:
self._targets = []
logger.error('UNIT call to a subscriber on the same system, send nothing')
else:
self._targets = list(UNIT)
self._targets.remove(self._system)
# This is a new call stream, so log & report
self.STATUS[_slot]['RX_START'] = pkt_time
self.STATUS[_slot]['RX_TERMINATED'] = False
self.STATUS[_slot]['RX_CT'] = 'UNIT VOICE'
logger.info('(%s) *UNIT CALL START* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) UNIT: %s (%s), TS: %s, FORWARD: %s', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, self._targets)
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('UNIT VOICE,START,RX,{},{},{},{},{},{},{}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), self._targets).encode(encoding='utf-8', errors='ignore'))
for _target in self._targets:
systems[_target].bridge_unit(
self, _peer_id, _rf_src, _dst_id, _stream_id, _slot,
_frame_type, _dtype_vseq, _data, pkt_time)
# Final actions - Is this a voice terminator?
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM) and (not self.STATUS[_slot]['RX_TERMINATED']):
self.STATUS[_slot]['RX_TERMINATED'] = True
self._targets = []
call_duration = pkt_time - self.STATUS[_slot]['RX_START']
logger.info('(%s) *UNIT CALL END* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) UNIT %s (%s), TS %s, Duration: %.2f', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, call_duration)
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('UNIT VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), call_duration).encode(encoding='utf-8', errors='ignore'))
# Mark status variables for use later
self.STATUS[_slot]['RX_PEER'] = _peer_id
self.STATUS[_slot]['RX_SEQ'] = _seq
self.STATUS[_slot]['RX_RFS'] = _rf_src
self.STATUS[_slot]['RX_TYPE'] = _dtype_vseq
self.STATUS[_slot]['RX_TGID'] = _dst_id
self.STATUS[_slot]['RX_TIME'] = pkt_time
self.STATUS[_slot]['RX_STREAM_ID'] = _stream_id
# Forward a bridged unit (private) call INTO this HBP repeater system (this
# system is the target). Unit calls are sent as-is (no TGID/LC rewrite); the
# timeslot's contention policy still applies. Only the two stream-timeout
# checks are active for unit calls (the group-hangtime checks are disabled).
def bridge_unit(self, _src, _peer_id, _rf_src, _dst_id, _stream_id, _slot,
_frame_type, _dtype_vseq, _data, _pkt_time):
_target_status = self.STATUS
if (_dst_id == _target_status[_slot]['RX_TGID']) and ((_pkt_time - _target_status[_slot]['RX_TIME']) < STREAM_TO):
if _src.should_log_contention(_stream_id, _slot, _frame_type, _dtype_vseq):
logger.info('(%s) Call not routed to destination %s, matching call already active on target: HBSystem: %s, TS: %s, DEST: %s', _src._system, int_id(_dst_id), self._system, _slot, int_id(_target_status[_slot]['RX_TGID']))
return
if (_dst_id == _target_status[_slot]['TX_TGID']) and (_rf_src != _target_status[_slot]['TX_RFS']) and ((_pkt_time - _target_status[_slot]['TX_TIME']) < STREAM_TO):
if _src.should_log_contention(_stream_id, _slot, _frame_type, _dtype_vseq):
logger.info('(%s) Call not routed for subscriber %s, call route in progress on target: HBSystem: %s, TS: %s, DEST: %s, SUB: %s', _src._system, int_id(_rf_src), self._system, _slot, int_id(_target_status[_slot]['TX_TGID']), int_id(_target_status[_slot]['TX_RFS']))
return
# Record target information if this is a new call stream on the slot
if (_target_status[_slot]['TX_STREAM_ID'] != _stream_id):
_target_status[_slot]['TX_START'] = _pkt_time
_target_status[_slot]['TX_TERMINATED'] = False
_target_status[_slot]['TX_TGID'] = _dst_id
_target_status[_slot]['TX_STREAM_ID'] = _stream_id
_target_status[_slot]['TX_RFS'] = _rf_src
_target_status[_slot]['TX_PEER'] = _peer_id
logger.info('(%s) Unit call bridged to HBP System: %s TS: %s, UNIT: %s', _src._system, self._system, _slot, int_id(_dst_id))
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('UNIT VOICE,START,TX,{},{},{},{},{},{}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id)).encode(encoding='utf-8', errors='ignore'))
# On the voice terminator, mark the TX stream ended so the stream-trimmer
# doesn't later synthesize a duplicate timeout END for a cleanly-ended call.
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
_target_status[_slot]['TX_TERMINATED'] = True
# Set values for the contention handler to test on the next frame
_target_status[_slot]['TX_TIME'] = _pkt_time
_target_status[_slot]['TX_TYPE'] = _dtype_vseq
self.send_system(_data)
def dmrd_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data):
if _call_type == 'group':
self.group_received(_peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data)
elif _call_type == 'unit':
if self._system not in UNIT:
logger.error('(%s) *UNIT CALL NOT FORWARDED* UNIT calling is disabled for this system (INGRESS)', self._system)
else:
self.unit_received(_peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data)
elif _call_type == 'vcsbk':
logger.debug('CSBK recieved, but HBlink does not process them currently')
else:
logger.error('Unknown call type recieved -- not processed')
#
# Socket-based reporting section (newline-delimited JSON; see hblink.reportFactory)
#
# Build a JSON-serializable view of the BRIDGES (conference bridge) structure.
def json_bridges(_bridges):
out = {}
for bridge, members in _bridges.items():
out[bridge] = [{
'SYSTEM': m['SYSTEM'],
'TS': m['TS'],
'TGID': int_id(m['TGID']),
'ACTIVE': m['ACTIVE'],
'TO_TYPE': m['TO_TYPE'],
'TIMER': m['TIMER'],
'TIMEOUT': m['TIMEOUT'],
'ON': [int_id(t) for t in m['ON']],
'OFF': [int_id(t) for t in m['OFF']],
} for m in members]
return out
class bridgeReportFactory(reportFactory):
def send_bridge(self):
self.send_clients({'type': 'bridges', 'bridges': json_bridges(BRIDGES)})
def send_initial(self, _client):
# A new consumer gets both the systems config and the bridge state.
self.send_to(_client, self.config_event())
self.send_to(_client, {'type': 'bridges', 'bridges': json_bridges(BRIDGES)})
def send_bridgeEvent(self, _data):
# Call sites pass a CSV string (kept to avoid churning the routing code);
# convert it to a JSON stream event. CSV fields are:
# call_type, action, trx, system, stream_id, peer, src, slot, dst[, duration]
if isinstance(_data, (bytes, bytearray)):
_data = _data.decode('utf-8', errors='ignore')
p = _data.split(',')
try:
event = {
'type': 'stream',
'call_type': p[0],
'action': p[1],
'trx': p[2],
'system': p[3],
'stream_id': int(p[4]),
'peer': int(p[5]),
'src': int(p[6]),
'slot': int(p[7]),
'dst': int(p[8]),
}
if len(p) > 9:
event['duration'] = float(p[9])
except (IndexError, ValueError):
logger.error('(REPORT) malformed bridge event: %s', _data)
return
self.send_clients(event)
#************************************************
# MAIN PROGRAM LOOP STARTS HERE
#************************************************
if __name__ == '__main__':
import argparse
import sys
import os
import signal
# Change the current directory to the location of the application
os.chdir(os.path.dirname(os.path.realpath(sys.argv[0])))
# CLI argument parser - handles picking up the config file from the command line, and sending a "help" message
parser = argparse.ArgumentParser()
parser.add_argument('-c', '--config', action='store', dest='CONFIG_FILE', help='/full/path/to/config.file (usually hblink.cfg)')
parser.add_argument('-r', '--rules', action='store', dest='RULES_FILE', help='/full/path/to/rules.file (usually rules.py)')
parser.add_argument('-l', '--logging', action='store', dest='LOG_LEVEL', help='Override config file logging level.')
cli_args = parser.parse_args()
# Ensure we have a path for the config file, if one wasn't specified, then use the default (top of file)
if not cli_args.CONFIG_FILE:
cli_args.CONFIG_FILE = os.path.dirname(os.path.abspath(__file__))+'/hblink.cfg'
# Call the external routine to build the configuration dictionary
CONFIG = config.build_config(cli_args.CONFIG_FILE)
# Ensure we have a path for the rules file, if one wasn't specified, then use the default (top of file)
if not cli_args.RULES_FILE:
cli_args.RULES_FILE = os.path.dirname(os.path.abspath(__file__))+'/rules.py'
# Start the system logger
if cli_args.LOG_LEVEL:
CONFIG['LOGGER']['LOG_LEVEL'] = cli_args.LOG_LEVEL
logger = log.config_logging(CONFIG['LOGGER'])
logger.info('\n\nCopyright (c) 2013, 2014, 2015, 2016, 2018, 2019, 2020\n\tThe Regents of the K0USY Group. All rights reserved.\n')
logger.debug('(GLOBAL) Logging system started, anything from here on gets logged')
# Create the name-number mapping dictionaries
peer_ids, subscriber_ids, talkgroup_ids = mk_aliases(CONFIG)
# Import the ruiles file as a module, and create BRIDGES from it
spec = importlib.util.spec_from_file_location("module.name", cli_args.RULES_FILE)
rules_module = importlib.util.module_from_spec(spec)
try:
spec.loader.exec_module(rules_module)
logger.info('(ROUTER) Routing bridges file found and bridges imported: %s', cli_args.RULES_FILE)
except (ImportError, FileNotFoundError):
sys.exit('(ROUTER) TERMINATING: Routing bridges file not found or invalid: {}'.format(cli_args.RULES_FILE))
# Build the routing rules file
BRIDGES = make_bridges(rules_module.BRIDGES)
# Build the per-frame routing lookup indexes from the rules
BRIDGE_SRC_INDEX, BRIDGE_BY_SYSTEM = index_bridges(BRIDGES)
# Get rule parameter for private calls
UNIT = rules_module.UNIT
# The asyncio entry point: signal handling, reporting, a UDP endpoint for each
# enabled system, and the rule-timer / stream-trimmer periodic tasks.
async def async_main():
global report_server
loop = asyncio.get_running_loop()
stop_event = asyncio.Event()
def shutdown(signum):
logger.info('(GLOBAL) SHUTDOWN: CONFBRIDGE IS TERMINATING WITH SIGNAL %s', signum)
hblink_handler(signum, None)
logger.info('(GLOBAL) SHUTDOWN: ALL SYSTEM HANDLERS EXECUTED - STOPPING')
stop_event.set()
for sig in (signal.SIGINT, signal.SIGTERM):
loop.add_signal_handler(sig, shutdown, sig)
# INITIALIZE THE REPORTING LOOP
if CONFIG['REPORTS']['REPORT']:
report_server = config_reports(CONFIG, bridgeReportFactory)
else:
report_server = None
logger.info('(REPORT) TCP Socket reporting not configured')
# HBlink instance creation
logger.info('(GLOBAL) HBlink \'bridge.py\' -- SYSTEM STARTING...')
for system in CONFIG['SYSTEMS']:
if CONFIG['SYSTEMS'][system]['ENABLED']:
if CONFIG['SYSTEMS'][system]['MODE'] == 'OPENBRIDGE':
systems[system] = routerOBP(system, CONFIG, report_server)
else:
systems[system] = routerHBP(system, CONFIG, report_server)
await loop.create_datagram_endpoint(
lambda s=systems[system]: s,
local_addr=(CONFIG['SYSTEMS'][system]['IP'], CONFIG['SYSTEMS'][system]['PORT']))
logger.debug('(GLOBAL) %s instance created: %s, %s', CONFIG['SYSTEMS'][system]['MODE'], system, systems[system])
# Initialize the rule timer (user-activated stuff) and the stream trimmer
loop.create_task(run_periodic(60, rule_timer_loop, '(ROUTER) rule timer'))
loop.create_task(run_periodic(1, stream_trimmer_loop, '(ROUTER) stream trimmer'))
await stop_event.wait()
asyncio.run(async_main())