this commit enables 3 strict pytest options:
strict_config - if any warnings encountered while parsing the pytest section of the configuration file will raise errors.
xfail_strict - if markers not registered in the markers section of the configuration file will raise errors.
strict-markers - if tests marked with @pytest.mark.xfail that actually succeed will by default fail the test suite
and fix errors that occur after enabling these options
Closesscylladb/scylladb#28859
Finishing the deprecation of the skip_mode function in favor of
pytest.mark.skip_mode. This PR is only cleaning and migrating leftover tests
that are still used and old way of skip_mode.
Closesscylladb/scylladb#28299
Function skip_mode works only on function and only in cluster test. This if OK
when we need to skip one test, but it's not possible to use it with pytestmark
to automatically mark all tests in the file. The goal of this PR is to migrate
skip_mode to be dynamic pytest.mark that can be used as ordinary mark.
Closesscylladb/scylladb#27853
[avi: apply to test/cluster/test_tablets.py::test_table_creation_wakes_up_balancer]
The test executes a LWT query in order to create a paxos state table and
verify the table properties. However, after executing the LWT query, the
table may not exist on all nodes but only on a quorum of nodes, thus
checking the properties of the table may fail if the table doesn't exist
on the queried node.
To fix that, execute a group0 read barrier to ensure the table is
created on all nodes.
Fixesscylladb/scylladb#27398Closesscylladb/scylladb#27401
For tables of special types that can be located: MV, CDC, and paxos
table, we should not use tombstone_gc=repair mode because colocated
tablets are never repaired, hence they will not have repair_time set and
will never be GC'd using 'repair' mode.
With the introduction of colocated tables, all the tablet transitions
now operate on groups of colocated tablets instead of individual
tablets. such is tablet migration, and also tablet repair.
The tablet repair currently doesn't work on individual tablets due to
the limitations in the tablet map being shared. The way it was
implemented to work on a group of colocated tablets is by repairing all
the colocated tablets together, using a dedicated rpc, and setting a
shared repair_time in the shared tablet map. It was implemented this
way because we wanted to have some way to repair the tablets of a
colocated table.
However, we want to change this in the next release so that it will be
possible to repair the tablets of a colocated table individually. In
order to simplify and prepare for the future change, we prefer until
then to not repair colocated tables at all. otherwise, we will need to
support both the shared repair and individual repair together for a long
time, and the upgrade will be more complicated.
We change the handling of the tablet 'repair' transition to repair only
the base table's tablets. It means it will not be possible to request
tablet repair for a non-base colocated table such as local MV, CDC and
paxos table. This restriction will be temporary until a later release
where we will suuport repairing colocated tablets.
This is a reasonable restriction because repair for these kind of tables
is not required or as important as for normal tables.
Fixesscylladb/scylladb#27119
- Disable tablets in `test_migration_on_existing_raft_topology`.
Because views on tablets are experimental now, we can safely
assume that view building coordinator will start with view build status
on raft.
- Add error injection to pause view building on worker.
Used to pause view building process, there is analogous error injection
in view_builder.
- Do a read barrier in `test_view_in_system_tables`
Increases test stability by making sure that the node sees up-to-date
group0 state and `system.built_views` is synced.
- Wait for view is build in some tests
Increases tests stability by making sure that the view is built.
- Remove xfail marker from `test_tablet_streaming_with_unbuilt_view`
This series fix https://github.com/scylladb/scylladb/issues/21564
and this test should work now.
This commits introduces an config option 'tablet_load_stats_refresh_interval_in_seconds'
that allows overriding the default value without using error injection.
Fixesscylladb/scylladb#24641Closesscylladb/scylladb#24746