Migrate runtime pytest.skip() calls across 34 files to use the typed
skip_env() wrapper from test.pylib.skip_types.
These sites skip at runtime because a required feature, config option,
library version, build mode, or runtime topology is not available.
Also fixes 'raise pytest.skip(...)' in test_audit.py — skip_env()
already raises internally, so the explicit raise was incorrect.
Each file gains one new import:
from test.pylib.skip_types import skip_env
Remove many unused "import" statements or parts of import statement.
All of them were detected by Copilot, but I verified each one manually
and prepared this patch.
Signed-off-by: Nadav Har'El <nyh@scylladb.com>
Closesscylladb/scylladb#27676
copilot noticed in that in in many of Alternator tests, we have some
unnecessary assignments. For example, in a few places, we use the idiom:
with pytest.raises(...):
ret = ...
The "ret=" part is unnecessary, as this test expects the statement to
fail (hence the raises()), and ret is never assigned. The assignment
was only there because we copied this statement from another place in
the test, which does expect the statement to pass and wants to validate
the returned value.
So we should just drop the "ret=" from these tests.
Another common occurance is that we used the idiom
response = table.do_something()
Without checking the response and no intention to check it (either we
know it will work, or we just want to check it doesn't throw). So we
can drop the "response=" here too.
All of the unused variables in this patch were discovered by Copilot,
but I reviewed each of them carefully myself and prepared this patch.
Signed-off-by: Nadav Har'El <nyh@scylladb.com>
Fix unlikely use-after-free in `encode_paging_state`. The function
incorrectly assumes that current position to encode will always have
data for all clustering columns the schema defines. It's possible to
encounter current position having less than all columns specified, for
eample in case of range tombstone. Those don't happen in Alternator
tables as DynamoDB doesn't allow range deletions and clustering key
might be of size at most 1. Alternator api can be used to read
scylla system tables and those do have range tombstones with more
than single clustering column.
The fix is to stop trying to encode columns, that don't have the value -
they are not needed anyway, as there's no possible position with those
values (range tombstone made sure of that).
Fixes#27001Fixes#27125Closesscylladb/scylladb#26960
Now that the previous patch made it possible to write to system tables
in Alternator tests, this patch introduces utility functions for changing
the configuration - scylla_config_write() in addition to the
scylla_config_read() we already had, and scylla_config_temporary() to
temporarily change a configurable parameter and then restore it to its
old value.
This patch adds a silly test that temporarily modifies the
query_tombstone_page_limit configuration parameter. Later we can
add more tests that use the new test functions for more "serious"
testing of real features. In particular, we don't have an Alternator
test for the max_concurrent_requests_per_shard configuration - and
I want to write one.
Signed-off-by: Nadav Har'El <nyh@scylladb.com>
In commit 44a1daf we added the ability to read system tables through
the DynamoDB API (actually, the Scan and Query requests only).
This ability is useful for tests, and can also be useful to users who
want to read information that is only available through system tables.
This patch adds support also for *writing* into system tables. This will
be useful for Alternator tests, were we want to temporarily change
some live-updatable configuration option - and so far haven't been
able to do that like we did do in some cql-pytest tests.
For reasons explained in issue #23218, only superuser roles are allowed to
write to system tables - it is not enough for the role to be granted
MODIFY permissions on the system table or on ALL KEYSPACES. Moreover,
the ability to modify system tables carries special risks, so this
patch only allows writes to the system tables if a new configuration
option "alternator_allow_system_table_write" turned on. This option is
turned off by default.
This patch also includes a test for this new configuration-writing
capability. The test scripts test/alternator/run and test.py now
run Scylla with alternator_allow_system_table_write turned on, but
the new test can also run without this option, and will be skipped
in that case (to allow running the test suite against some manually-
run instance of Scylla).
Fixes: #12348
Signed-off-by: Nadav Har'El <nyh@scylladb.com>
This patch adds a regression test for the feature added in the previous patch,
i.e that the system.clients virtual table also lists ongoing Alternator request.
The new test reads the system.clients system table using an Alternator Scan
request, so it should see its own request - at least - in the result. It
verifies that it sees Alternator requests (at least one), and that these
requests have the expected fields set, and for a couple of fields, we
even know which value to expect (the "client_type" field is "alternator",
and the "ssl_enabled" field depends on whether the test is checking an
http:// or https:// URL (you can try both in test/alternator/run - by
using or not using the "--https" parameter).
The new test fails before the previous patch (because system.clients
will not list any Alternator connection), and passes after it.
As all tests in test_system_tables.py for Scylla-specific system tables,
this test is marked scylla_only and skipped when running on AWS DynamoDB.
Signed-off-by: Nadav Har'El <nyh@scylladb.com>
Fixes#13332
The tests user the discriminator "system" as prefix to assume keyspaces are marked
"internal" inside scylla. This is not true in enterprise universe (replicated key
provider). It maybe/probably should, but that train is sailing right now.
Fix by removing one assert (not correct) and use actual API info in the alternator
test.
Closes#13333
Instead of lengthy blurbs, switch to single-line, machine-readable
standardized (https://spdx.dev) license identifiers. The Linux kernel
switched long ago, so there is strong precedent.
Three cases are handled: AGPL-only, Apache-only, and dual licensed.
For the latter case, I chose (AGPL-3.0-or-later and Apache-2.0),
reasoning that our changes are extensive enough to apply our license.
The changes we applied mechanically with a script, except to
licenses/README.md.
Closes#9937
The test test_fetch_from_system_tables tests Alternator's system-table
feature by reading from all system tables. The intention was to confirm
we don't crash reading any of them - as they have different schemas and
can run into different problems (we had such problems in the initial
implementation). The intention was not to read *a lot* from each table -
we only make a single "Scan" call on each, to read one page of data.
However, the Scan call did not set a Limit, so the single page can get
pretty big.
This is not normally a problem, but in extremely slow runs - such as when
running the debug build on an extremely overcommitted test machine (e.g.,
issue #7706) reading this large page may take longer than our default
timeout. I'll send a separate patch for the timeout issue, but for now,
there is really no reason why we need to read a big page. It is good
enough to just read 50 rows (with Limit=50). This will still read all
the different types and make the test faster.
As an example, in the debug run on my laptop, this test spent 2.4
seconds to read the "compaction_history" table before this patch,
and only 0.1 seconds after this patch. 2.4 seconds is close to our
default timeout (10 seconds), 0.1 is very far.
Fixes#7706
Signed-off-by: Nadav Har'El <nyh@scylladb.com>
Message-Id: <20201207075112.2548178-1-nyh@scylladb.com>
Merged patch series from Piotr Sarna:
This series allows reading rows from Scylla's system tables
via alternator by using a virtual interface.
If a Query or Scan request intercepts a table name with the following
pattern: .scylla.alternator.KEYSPACE_NAME.TABLE_NAME, it will read
the data from Scylla's KEYSPACE_NAME.TABLE_NAME table.
The interface is expected to only return data for Scylla system tables
and trying to access regular tables via this interface is expected
to return an error.
This series comes with tests (alternator-test, scylla_only).
Fixes#6122
Tests: alternator-test(local,remote (to verify that scylla_only works)
Piotr Sarna (5):
alternator: add fallback serialization for all types
alternator: add fetching static columns if they exist
alternator: add a way of accessing system tables from alternator
alternator-test: add scylla-only test for querying system tables
docs: add an entry about accessing Scylla system tables
alternator-test/test_system_tables.py | 61 +++++++++++++++++++++++++++
alternator/executor.cc | 38 ++++++++++++++++-
alternator/executor.hh | 1 +
alternator/serialization.cc | 11 +++--
docs/alternator/alternator.md | 15 +++++++
5 files changed, 122 insertions(+), 4 deletions(-)
create mode 100644 alternator-test/test_system_tables.py