Instead of lengthy blurbs, switch to single-line, machine-readable
standardized (https://spdx.dev) license identifiers. The Linux kernel
switched long ago, so there is strong precedent.
Three cases are handled: AGPL-only, Apache-only, and dual licensed.
For the latter case, I chose (AGPL-3.0-or-later and Apache-2.0),
reasoning that our changes are extensive enough to apply our license.
The changes we applied mechanically with a script, except to
licenses/README.md.
Closes#9937
It is no longer called once for a given view_info, so the name
"initialize" is not appropriate.
This patch splits the "initialize" method into the "make" part, which
makes a new base_info object, and the "set" part, which changes the
current base_info object attached to the view.
The view_info object, which is attached to the schema object of the
view, contains a data structure called
"base_non_pk_columns_in_view_pk". This data structure contains column
ids of the base table so is valid only for a particular version of the
base table schema. This data structure is used by materialized view
code to interpret mutations of the base table, those coming from base
table writes, or reads of the base table done as part of view updates
or view building.
The base table schema version of that data structure must match the
schema version of the mutation fragments, otherwise we hit undefined
behavior. This may include aborts, exceptions, segfaults, or data
corruption (e.g. writes landing in the wrong column in the view).
Before this patch, we could get schema version mismatch here after the
base table was altered. That's because the view schema does not change
when the base table is altered.
Part of the fix is to extract base_non_pk_columns_in_view_pk into a
third entitiy called base_dependent_view_info, which changes both on
base table schema changes and view schema changes.
It is managed by a shared pointer so that we can take immutable
snapshots of it, just like with schema_ptr. When starting the view
update, the base table schema_ptr and the corresponding
base_dependent_view_info have to match. So we must obtain them
atomically, and base_dependent_view_info cannot change during update.
Also, whenever the base table schema changes, we must update
base_dependent_view_infos of all attached views (atomically) so that
it matches the base table schema.
Refs #7061.
The header sits in many other headers, but there's a handy
schema_fwd.hh that's tiny and contains needed declarations
for other headers. So replace shema.hh with schema_fwd.hh
in most of the headers (and remove completely from some).
Signed-off-by: Pavel Emelyanov <xemul@scylladb.com>
Message-Id: <20200303102050.18462-1-xemul@scylladb.com>
The method view_info::partition_ranges() is unused.
Also drop the now-dead _partition_ranges data member.
Signed-off-by: Dejan Mircevski <dejan@scylladb.com>
Previous assumption was that there can only be one regular base column
in the view key. The assumption is still correct for tables created
via CQL, but it's internally possible to create a view with multiple
such columns - the new assumption is that if there are multiple columns,
they share their liveness.
This patch is vital for indexing to work properly on alternator,
so it would be best to solve the issue upstream. I strived to leave
the existing semantics intact as long as only up to one regular
column is part of the materialized view primary key, which is the case
for Scylla's materialized views. For alternator it may not be true,
but all regular columns in alternator share liveness info (since
alternator does not support per-column TTL), which is sufficient
to compute view updates in a consistent way.
Fixes#5006
Tests: unit(dev), alternator(test_gsi_update_second_regular_base_column, tic-tac-toe demo)
Message-Id: <c9dec243ce903d3a922ce077dc274f988bcf5d57.1567604945.git.sarna@scylladb.com>
It's detrimental to keep querying index manager whether a view
is backing a secondary index every time, so this value is cached
at construct time.
At the same time, this value is not simply passed to view_info
when being created in secondary index manager, in order to
decouple materialized view logic from secondary indexes as much as
possible (the sole existence of is_index() is bad enough).
Replace stdx::optional and stdx::string_view with the C++ std
counterparts.
Some instances of boost::variant were also replaced with std::variant,
namely those that called seastar::visit.
Scylla now requires GCC 8 to compile.
Signed-off-by: Duarte Nunes <duarte@scylladb.com>
Message-Id: <20190108111141.5369-1-duarte@scylladb.com>
Instead of lazily-initializing the regular base column in the view's
PK field, explicitly initialize it. This will be used by future
patches that don't have access to the schema when wanting to obtain
that column.
Signed-off-by: Duarte Nunes <duarte@scylladb.com>
This patch stores the base_non_pk_column_in_view column as column_id,
which is more convenient, and it also stores a two-level optional to
encode both lazy initialization and the absence of such a column.
Signed-off-by: Duarte Nunes <duarte@scylladb.com>
The write path uses a base schema at a particular version, and we
want it to use the materialized views at the corresponding version.
To achieve this, we need to map the state currently in db::view::view
to a particular schema version, which this patch does by introducing
the view_info class to hold the state previously in db::view::view,
and by having a view schema directly point to it.
The changes in the patch are thus:
1) Introduce view_info to hold the extra view state;
2) Point to the view_info from the schema;
3) Make the functions in the now stateless db::view::view non-member;
4) Remove the db::view::view class.
All changes are structural and don't affect current behavior.
Signed-off-by: Duarte Nunes <duarte@scylladb.com>