The reader used to read the sstables was not closed. This could
sometimes trigger an abort(), because the reader was destroyed, without
it being closed first.
Why only sometimes? This is due to two factors:
* read_mutation_from_flat_mutation_reader() - the method used to extract
a mutation from the reader, uses consume(), which does not trigger
`set_close_is_required()` (#16520). Due to this, the top-level
combined reader did not complain when destroyed without close.
* The combined reader closes underlying readers who have no more data
for the current range. If the circumstances are just right, all
underlying readers are closed, before the combined reader is
destoyed. Looks like this is what happens for the most time.
This bug was discovered in SCT testing. After fixing #16520, all
invokations of `scylla-sstable`, which use this code would trigger the
abort, without this patch. So no further testing is required.
Fixes: #16519
Closes scylladb/scylladb#16521
(cherry picked from commit da033343b7)