When an Alternator table has partition keys or sort keys of type "bytes" (blobs), a Scan or Query which required paging used to fail - we used an incorrect function to output LastEvaluatedKey (which tells the user where to continue at the next page), and this incorrect function was correct for strings and numbers - but NOT for bytes (for bytes, we need to encode them as base-64). This patch also includes two tests - for bytes partition key and for bytes sort key - that failed before this patch and now pass. The test test_fetch_from_system_tables also used to fail after a Limit was added to it, because one of the tables it scans had a bytes key. That test is also fixed by this patch. Fixes #7768 Signed-off-by: Nadav Har'El <nyh@scylladb.com> Message-Id: <20201207175957.2585456-1-nyh@scylladb.com>