Files
scylladb/test/boost
Botond Dénes 1d9b5911fe time_series_sstable_set::create_single_key_sstable_reader(): fix use-after-free
The optimal path of said method mistakenly captures `pos` (a local
variable) in its reader factory method and passes a temporary range
implicitly constructed from said `pos` as the range parameter to the
sstable reader. This will lead to the sstable reader using a dangling
range and will result in returning no result for queries. This patch
fixes this bug and adds a unit test to cover this code path.

Fixes #8138.

Signed-off-by: Botond Dénes <bdenes@scylladb.com>
Message-Id: <20210226143111.104591-2-bdenes@scylladb.com>
2021-02-26 23:57:25 +02:00
..
2020-11-12 12:36:13 +01:00
2021-01-15 18:28:24 +01:00
2020-08-11 10:37:34 +08:00
2020-11-03 21:30:11 +03:00