Files
scylladb/replica
Benny Halevy e9e66f3ca7 database: drop_table_on_all_shards: limit truncated_at time
The infinetely high time_point of `db_clock::time_point::max()`
used in ba42852b0e
is too high for some clients that can't represent
that as a date_time string.

Instead, limit it to 9999-12-31T00:00:00+0000,
that is practically sufficient to ensure truncation of
all sstables and should be within the clients' limits.

Fixes #12239

Signed-off-by: Benny Halevy <bhalevy@scylladb.com>

Closes #12273
2022-12-13 16:46:20 +02:00
..