When an Alternator table has partition keys or sort keys of type "bytes"
(blobs), a Scan or Query which required paging used to fail - we used
an incorrect function to output LastEvaluatedKey (which tells the user
where to continue at the next page), and this incorrect function was
correct for strings and numbers - but NOT for bytes (for bytes, we
need to encode them as base-64).
This patch also includes two tests - for bytes partition key and
for bytes sort key - that failed before this patch and now pass.
The test test_fetch_from_system_tables also used to fail after a
Limit was added to it, because one of the tables it scans had a bytes
key. That test is also fixed by this patch.
Fixes #7768
Signed-off-by: Nadav Har'El <nyh@scylladb.com>
Message-Id: <20201207175957.2585456-1-nyh@scylladb.com>
(cherry picked from commit 86779664f4)