Compare the existing PVC's capacity against the source volume size
recorded in the backup volume info (#10506) before any side effect and
skip the volume when it is too small, so the restore fails early instead
of running out of space midway. For the block data mover the source size
is the device size; for the file system data movers it is the logical
size of the backed-up files, a lower bound since file system metadata is
not accounted for.
The file system path reads the size from the volume info already carried
in RestoreData. The PVC CSI RIA has no access to the volume info, so the
restore engine carries the size on the PVC item through a Velero-internal
annotation, the same mechanism as the selected-node carrier; both carrier
annotations are stripped before the item is created in the cluster.
The check is skipped when the source size is unknown (backups taken
before it was recorded) or the PVC's capacity is not reported.
Signed-off-by: chlins <chlins.zhang@gmail.com>
* Scope schedule and repo CLI list calls to the Velero namespace
velero schedule get, velero schedule describe, velero schedule
pause/unpause and velero repo get built a ctrlclient.ListOptions with a
LabelSelector but no Namespace, so the list ran across every namespace in
the cluster. Their single-name paths in the same functions already scope
to f.Namespace(), and every sibling command (backup get, restore get,
backup describe, restore describe, snapshot-location get, schedule
delete) passes Namespace too, so the omission was an oversight rather
than intent.
The read commands print another installation's Schedules and
BackupRepositories. runPause is worse: velero schedule pause --all and
velero schedule unpause --all fetch Schedules from every namespace and
then write Spec.Paused on each, so pausing one installation's schedules
pauses every other installation's schedules as well.
Add Namespace: f.Namespace() to the four List calls:
pkg/cmd/cli/schedule/get.go:61
pkg/cmd/cli/schedule/describe.go:59
pkg/cmd/cli/schedule/pause.go:114
pkg/cmd/cli/repo/get.go:61
Neither pkg/cmd/cli/schedule nor pkg/cmd/cli/repo had any tests, so the
regression tests are new files. Each seeds a fake client with one object
in the Velero namespace and one in another-velero, and asserts the second
is neither listed, described, nor paused.
Signed-off-by: Max Freedom Pollard <272618364+MaxFreedomPollard@users.noreply.github.com>
* Add changelog for PR 10482
Signed-off-by: Max Freedom Pollard <272618364+MaxFreedomPollard@users.noreply.github.com>
---------
Signed-off-by: Max Freedom Pollard <272618364+MaxFreedomPollard@users.noreply.github.com>
formatUserPriorities stripped only spaces, so an enableapigroupversions
ConfigMap written with CRLF line endings (common for files edited on
Windows) kept a trailing carriage return in each version string, e.g.
"v2beta1\r". versionsContain compares versions with equality, so the
user priority never matched and was silently ignored. Trim the trailing
carriage return so stored versions match again.
Signed-off-by: HeonJe LEE <lhjnano@gmail.com>
* Fix datamover backup arg mismatch for CSI CBT service account name
The exposer built the pod command with --csi-snapshot-metadata-service-sa,
but the datamover backup command only registered --cbt-sa-name. cobra
rejects unknown flags, so the data mover pod exited immediately whenever
a dedicated CBT service account was configured -- and the reverse also
held: since the flags never matched, the SA name never actually reached
the pod, so any code path depending on it stayed unreachable.
Not limited to the block data mover: this line sits outside the
DataMoverTypeVeleroBlock gate and the cbtInfo != nil gate, so it fires
for any CSI snapshot data-movement backup.
Fix: emit --cbt-sa-name (already consumed by the backup command), naming
it consistently with the other CBT flags on the same line (--change-id,
--volume-id, --snapshot-id).
Add a regression test asserting the emitted flag string parses cleanly
against NewBackupCommand's own flag set, so the two sides can't drift
apart again without a test failure.
* Add changelog for #10318
Signed-off-by: Tiger Kaovilai <tkaovila@redhat.com>
* Add MustIncludeAdditionalItemPVCs structure in backup. It's used to track PVCs returned by BIA with mustIncluded annotaion and PVC is excluded from backup by global filter.
* Modfiy the volumeHelper interface to add a parameter function for ShouldPerformFSBackup.
* Modify to support fine-grained backup filters.
* Modify according to comments. Use a read-only interface to replace the parameter function.
Signed-off-by: Xun Jiang <xun.jiang@broadcom.com>
* Add block data mover support for Velero backup/restore describe CLI.
Update output tests to accommodate RestoreType in VolumeInfo
This commit addresses the compilation and assertion errors caused by the introduction of `RestoreType` in `VolumeInfo` and the separation of `SnapshotDataMovementInfo` / `PodVolumeInfo` into their backup and restore counterparts. It fixes references across the test fixtures and the print guard conditions in `restore_describer.go`.
* Modify according to comments
* Add missing JSON tag in the VolumeInfo structures.
* Get uploaderType from the DU and DD's dataMover for the data mover volume info.
* Add IncrementalSize in the data mover volume info.
* Add existingVolumeDataPolicy and restoreType in the restore describe CLI output
* Add more UTs.
* Add some fields value setting that were previously missed.
* Fix the timestamp compare error only found in the GitHub action.
Signed-off-by: Xun Jiang <xun.jiang@broadcom.com>
Co-authored-by: Cursor <cursoragent@cursor.com>
An in-place restore onto a different volume than the one backed up is
unsafe: an incremental (CBT) restore computes deltas against a different
volume lineage, and even a full restore would patch and write into an
unrelated volume. Verify the existing PVC is bound and still bound to
the PV recorded at backup time before any side effect, on both the CSI
data mover path (using the backed-up PVC's volume name) and the file
system path (using the PVC-to-PV mapping from the backup volume info).
The PV comparison is skipped for namespace-mapped restores, where the
target PVC is necessarily bound to a different PV (the documented
cross-namespace clone-and-restore workflow).
Signed-off-by: chlins <chlins.zhang@gmail.com>
* Enforce resource filters on cluster-wide items
When backups query all namespaces (wildcard or omitted includes),
the item collector retrieved resources in bulk, bypassing
per-namespace resource filter policies in Stage 1 collection.
This caused resources not listed in the policy to be backed up.
To preserve cluster-wide query performance while enforcing policy
rules, evaluate namespace exclusions, resource kind allowlists,
and label selectors in memory for each collected item.
Signed-off-by: Adam Zhang <adam.zhang@broadcom.com>
* Optimize in-memory resource filter checks
Optimize per-item filter evaluation in the item collector:
- Precalculate GroupResource string once per resource type
- Skip filter policy evaluation when no namespaced policies exist
- Restrict in-memory filtering to cluster-wide queries
- Cache consecutive namespace lookups across collected items
- Lazily extract resource labels only when selectors are present
Signed-off-by: Adam Zhang <adam.zhang@broadcom.com>
---------
Signed-off-by: Adam Zhang <adam.zhang@broadcom.com>