Ben McClelland 51c28734fb fix: harden RC device initialization
Make an explicit RC device selection override any GID hint,
matching the --rc-device contract. A stale hint should not
prevent a named HCA from starting.

Query the selected port before allocating the protection domain and fail initialization when that query fails. Continuing with a zero LID advertises an invalid endpoint on InfiniBand and turns a clear startup error into a later RDMA data-plane failure.
2026-09-26 13:03:10 -07:00
..
2026-09-26 13:03:10 -07:00