Fix RX hang time bug and make all log messages consistent
Critical bug fix: - RX terminator was not setting end_time, causing hang_duration=0.00s - Added current_stream.end_time = time() to RX terminator handler - This fixes hang times ending immediately instead of waiting 10s Log message consistency: - Changed all TX logs to use 'dst=' instead of 'tgid=' to match RX - Added 'entering hang time' message to TX terminator to match RX - All stream end logs now have identical format Before fix: - TX hang time completed: hang_duration=10.52s (correct) After fix: - Both RX and TX should show hang_duration=10.00s Example logs: - RX stream started: src=..., dst=... - TX stream started: from repeater X, src=..., dst=... - RX stream ended: reason=terminator - entering hang time (10.0s) - TX stream ended: reason=terminator - entering hang time (10.0s) - RX hang time completed: hang_duration=10.00s - TX hang time completed: hang_duration=10.00s
This commit is contained in:
1 parent
eaa84581dd
commit
bc5eaaa8b5
1 file changed
+6
-3
+6
-3
@@ -1539,6 +1539,7 @@ class HBProtocol(DatagramProtocol):
|
||||
if _is_terminator and current_stream and not current_stream.ended:
|
||||
# DMR terminator detected - end stream immediately and start hang time
|
||||
current_stream.ended = True
|
||||
current_stream.end_time = time() # Critical: set end_time for hang calculation!
|
||||
hang_time = CONFIG.get('global', {}).get('stream_hang_time', 10.0)
|
||||
duration = time() - current_stream.start_time
|
||||
LOGGER.info(f'RX stream ended on repeater {int.from_bytes(repeater_id, "big")} slot {_slot}: '
|
||||
@@ -1700,7 +1701,7 @@ class HBProtocol(DatagramProtocol):
|
||||
LOGGER.info(f'TX stream started on repeater {int.from_bytes(repeater.repeater_id, "big")} slot {slot}: '
|
||||
f'from repeater {source_repeater_id}, '
|
||||
f'src={int.from_bytes(rf_src, "big")}, '
|
||||
f'tgid={int.from_bytes(dst_id, "big")}')
|
||||
f'dst={int.from_bytes(dst_id, "big")}')
|
||||
|
||||
# Emit stream_start event for dashboard
|
||||
self._events.emit('stream_start', {
|
||||
@@ -1725,14 +1726,16 @@ class HBProtocol(DatagramProtocol):
|
||||
duration = current_time - current_stream.start_time
|
||||
current_stream.end_time = current_time
|
||||
current_stream.ended = True
|
||||
hang_time = CONFIG.get('global', {}).get('stream_hang_time', 10.0)
|
||||
|
||||
# Log at INFO level with consistent format
|
||||
LOGGER.info(f'TX stream ended on repeater {int.from_bytes(repeater.repeater_id, "big")} slot {slot}: '
|
||||
f'src={int.from_bytes(rf_src, "big")}, '
|
||||
f'tgid={int.from_bytes(dst_id, "big")}, '
|
||||
f'dst={int.from_bytes(dst_id, "big")}, '
|
||||
f'duration={duration:.2f}s, '
|
||||
f'packets={current_stream.packet_count}, '
|
||||
f'reason=terminator')
|
||||
f'reason=terminator - '
|
||||
f'entering hang time ({hang_time}s)')
|
||||
|
||||