Fix READ(6)/WRITE(6)
LBA in those commands is 3 bytes long, not 2. git-svn-id: http://svn.code.sf.net/p/scst/svn/trunk@5414 d57e44dd-8a1f-0410-8b47-8ef2f437770f
This commit is contained in:
@@ -122,7 +122,7 @@ static int get_cdb_info_verify16(struct scst_cmd *cmd,
|
||||
const struct scst_sdbops *sdbops);
|
||||
static int get_cdb_info_len_1(struct scst_cmd *cmd,
|
||||
const struct scst_sdbops *sdbops);
|
||||
static int get_cdb_info_lba_2_len_1_256(struct scst_cmd *cmd,
|
||||
static int get_cdb_info_lba_3_len_1_256(struct scst_cmd *cmd,
|
||||
const struct scst_sdbops *sdbops);
|
||||
static int get_cdb_info_bidi_lba_4_len_2(struct scst_cmd *cmd,
|
||||
const struct scst_sdbops *sdbops);
|
||||
@@ -313,9 +313,9 @@ static const struct scst_sdbops scst_scsi_op_table[] = {
|
||||
SCST_TEST_IO_IN_SIRQ_ALLOWED|
|
||||
#endif
|
||||
SCST_WRITE_EXCL_ALLOWED,
|
||||
.info_lba_off = 2, .info_lba_len = 2,
|
||||
.info_lba_off = 1, .info_lba_len = 3,
|
||||
.info_len_off = 4, .info_len_len = 1,
|
||||
.get_cdb_info = get_cdb_info_lba_2_len_1_256},
|
||||
.get_cdb_info = get_cdb_info_lba_3_len_1_256},
|
||||
{.ops = 0x08, .devkey = " MV O OV ",
|
||||
.info_op_name = "READ(6)",
|
||||
.info_data_direction = SCST_DATA_READ,
|
||||
@@ -343,9 +343,9 @@ static const struct scst_sdbops scst_scsi_op_table[] = {
|
||||
SCST_TEST_IO_IN_SIRQ_ALLOWED|
|
||||
#endif
|
||||
SCST_WRITE_MEDIUM,
|
||||
.info_lba_off = 2, .info_lba_len = 2,
|
||||
.info_lba_off = 1, .info_lba_len = 3,
|
||||
.info_len_off = 4, .info_len_len = 1,
|
||||
.get_cdb_info = get_cdb_info_lba_2_len_1_256},
|
||||
.get_cdb_info = get_cdb_info_lba_3_len_1_256},
|
||||
{.ops = 0x0A, .devkey = " M O OV ",
|
||||
.info_op_name = "WRITE(6)",
|
||||
.info_data_direction = SCST_DATA_WRITE,
|
||||
@@ -6618,10 +6618,11 @@ static int get_cdb_info_len_1(struct scst_cmd *cmd,
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int get_cdb_info_lba_2_len_1_256(struct scst_cmd *cmd,
|
||||
static int get_cdb_info_lba_3_len_1_256(struct scst_cmd *cmd,
|
||||
const struct scst_sdbops *sdbops)
|
||||
{
|
||||
cmd->lba = get_unaligned_be16(cmd->cdb + sdbops->info_lba_off);
|
||||
cmd->lba = (cmd->cdb[sdbops->info_lba_off] & 0x1F) << 16;
|
||||
cmd->lba |= get_unaligned_be16(cmd->cdb + sdbops->info_lba_off + 1);
|
||||
/*
|
||||
* From the READ(6) specification: a TRANSFER LENGTH field set to zero
|
||||
* specifies that 256 logical blocks shall be read.
|
||||
|
||||