Two defects in the CSI snapshot exposer, both of which make every CBT
incremental silently degrade to a full backup on non-vSphere drivers.
1. getCBTInfo read the changeID from the freshly-created backup VSC's
status, which is populated asynchronously and is therefore usually
empty at that point. The handle is already present in the spec, so
fall back to vsc.Spec.Source.SnapshotHandle. vSphere is unaffected --
it takes the VSphereCNSChangeIDAnno branch and never reads the VSC
handle -- so this affects every other CSI driver.
2. createBackupVSC hardcoded DeletionPolicy: Delete, so the physical
snapshot was removed when the backup completed. Case-2 storage such
as Ceph RBD requires the base snapshot to survive for the next
GetMetadataDelta call, and the block-data-mover design specifies a
RetainSnapshot volume-policy parameter that was never implemented.
Inherit the source snapshot class's deletion policy instead, and
clean up the backup VSC object in CleanUp.
Adds TestCreateBackupVSCDeletionPolicy covering both Delete and Retain.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Signed-off-by: Tiger Kaovilai <tkaovila@redhat.com>
(cherry picked from commit f4867d0489788ce0c7a63ffe08da4ad059db88b4)
Signed-off-by: Tiger Kaovilai <tkaovila@redhat.com>
* Update CRDs and CLI to support in-place restore (#10038)
Update CRDs(Restore, DataDownload, PodVolumeRestore) and restore create CLI to support in-place restore
Signed-off-by: Wenkai Yin(尹文开) <yinw@vmware.com>
* Update Kopia(filesystem) uploader to support incremental and deleteExtraFile during restore (#10066)
Update Kopia(filesystem) uploader to support incremental and deleteExtraFile during restore
Signed-off-by: Wenkai Yin(尹文开) <yinw@vmware.com>
* Update Restore Exposer and PVC CSI to support in-place restore (#10104)
1. Update Restore Exposer to support exposing with existing PV for in-place restore
2. Update PVC CSI RIA to continue the restore process for in-place restore
Signed-off-by: Wenkai Yin(尹文开) <yinw@vmware.com>
* Update Block uploader to support increase restore (#10244)
Update Block uploader to support increase restore
Signed-off-by: Wenkai Yin(尹文开) <yinw@vmware.com>
* Update Exposer to recreate the target PV if the volume mode is different with the restore PVC (#10257)
Update Exposer to recreate the target PV if the volume mode is different with t
he restore PVC
Signed-off-by: Wenkai Yin(尹文开) <yinw@vmware.com>
* Preserve PVC selected-node annotation via carrier annotation for in-place restore
For in-place volume data restore, the existing PVC is deleted and
recreated. For StorageClasses with the WaitForFirstConsumer volume
binding mode, losing the volume.kubernetes.io/selected-node annotation
could let the scheduler place the recreated workload Pod in a different
zone than the original PV, leaving it stuck in ContainerCreating.
Instead of relying on RestoreItemAction execution order (the generic
PVC RIA unconditionally strips the selected-node annotation), the PVC
CSI RIA now captures the annotation from the existing PVC right before
deleting it and carries it on the target PVC via the Velero-internal
restore.velero.io/inplace-restore-selected-node annotation. The restore
engine translates the carrier back to the Kubernetes annotation after
all RestoreItemActions have run and always strips the carrier so it
never lands on the cluster.
This makes the behavior independent of RIA ordering: the Kubernetes
annotation is stripped by default on every path (including when the
target PVC does not exist and Velero falls back to provisioning a new
PVC), and preservation only happens when the CSI RIA explicitly
captured a value from the existing PVC.
Signed-off-by: chlins <chlins.zhang@gmail.com>
* Update the control path to make the in-place incremental restore with block data mover work E2E (#10410)
Update the control path to make the in-place incremental restore with block data mover work E2E
Signed-off-by: Wenkai Yin(尹文开) <yinw@vmware.com>
---------
Signed-off-by: Wenkai Yin(尹文开) <yinw@vmware.com>
Signed-off-by: chlins <chlins.zhang@gmail.com>
Co-authored-by: chlins <chlins.zhang@gmail.com>
Add GetVolumeSnapshotClassFromVolumePolicy helper and extend
GetVolumeSnapshotClass with a policySnapshotClass parameter. The new
tier sits between PVC annotation and backup annotation in the priority
chain: PVC annotation > volume policy > backup annotation > VSC label.
Ref: #8807
Signed-off-by: Shubham Pampattiwar <spampatt@redhat.com>
Change errors.Cause to errors.Is, because github.com/cockroachdb/errors
New() function create a error with error stack with depth 1, but
github.com/pkg/errors's New() function create error with no depth.
Signed-off-by: Xun Jiang <xun.jiang@broadcom.com>
* Fix UT failures caused by client-go version bump.
* Some modifications to enhance the UT stability.
* Fix UT errors: non-constant format string in call to ...
* Fix linter issues.
Signed-off-by: Xun Jiang <xun.jiang@broadcom.com>
This commit makes sure when a backup is deleted the controller will
delete the CSI snapshot even when the bakckup tarball is not uploaded.
fixes#8160
Signed-off-by: Daniel Jiang <daniel.jiang@broadcom.com>
The wait error changed from `timed out waiting for the condition`
to `context deadline exceeded`.
Signed-off-by: Xun Jiang <blackpigletbruce@gmail.com>
enabled, before executing the action.
The DeleteItemAction is not checked, because the DIA doesn't have a
method to get the action's plugin name.
This should be OK, because the CSI will check whether the VS and VSC
have a backup name annotation. If the VS and VSC is not handled by
the CSI plugin, then they don't have the annotation.
Signed-off-by: Xun Jiang <jxun@vmware.com>